PIE Products:
PIECAL 820 Process
Calibrator NEW!
Calibrate your process controls with the PIECAL 820

-
Technician friendly operation The unique and intuitive EZ-DIAL Double Click Menu makes it easier to setup
than other multifunction calibrators. Uses the same menus as the single
function PIECAL Evolution Calibrators.
-
Use it as a milliamp and
voltage calibrator Source 0 to 24.00 mA, 0 to 10.25 V dc and -10.00 to 110.00 mV Read to 24.00 mA, ±60.00 V dc and and -10.00 to 110.00 mV Simulate 2-Wire Transmitters Power up transmitters & loops with the built-in 24 V power supply Simplify
HART hookups with built-in 250 Ohm resistor
-
Calibrate directly in
temperature with 0.1°C/°F resolution The PIECAL 820 works with the instruments you use. Types J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) and P (Platinel
II) Pt 100 Ohm (3850, 3902, 3916, 3926) & 1000 Ohm (3850) Copper 10 & 50 Ohm, Nickel 100 and 120 Ohm
-
Checkout flow and
vibration systems Source & read frequency from 0 to 2000 CPM (Counts-Per-Minute),
0.00 to 999.99 Hz, 0.0 to 9999.9 Hz and 0.000 to 20.000 kHz
-
Checkout resistance
instruments Source and read resistance from 0.0 to 410.0 and 0 to 4001 ohms
-
Troubleshoot loop &
wiring problems ‘Beep’ out connections with the built-in continuity checker.
-
Repeatability you can
count on Accurate to ±0.008 mA, ±0.003 V, ±0.006 kHz, ±0.3°C/0.5°F
-
Guaranteed Compatible
with all Instrumentation Works with Rosemount & Honeywell Smart Transmitters, PLCs, DCSs,
Multi-Channel Recorders and other pulsed excitation devices
-
Easy to read
Turn on the backlight & easily see the display in dark areas of the plant.
-
Quickly set any three outputs
plus automatic stepping & ramping Easily set any value quickly with the adjustable “DIAL” plus store any three
output settings for instant recall with the EZ-CHECK™ switch. Choose between
2, 3, 5 & 11 steps to automatically increment the output in 100%, 50%, 25%
or 10% of span. Select RAMP to smoothly increase and decrease the output
between Zero and Span. Set step/ramp time to match your system from 5, 6, 7,
8, 10, 15, 20, 25, 30 and 60 seconds.
-
Measure temperature sensors,
frequency pickups, loop currents and voltage levels Check the values of your process sensors. Instantly recall MAX and MIN
values to see process variability.
-
Ready to go right out of the
box The PIECAL 820 comes with a rubber boot with tilt stand, deluxe carrying
case, four test leads with spade lugs for RTD and ohms, two test leads with
alligator clips for milliamp, volt, frequency & continuity and a free NIST
Certificate of Calibration.
-
Optional Accessories
Wire & Mini T/C Plug: J, T, E, K (020-0202); B, R/S, K (020-0203),
Calibration report with test data
Match the instrument you’re calibrating with the PIECAL 820! Milliamp DC Volts Thermocouple RTD Frequency Continuity
.......................................................................................................................................
Milliamp Loop Calibrators
PIECAL Model 334 - Just Like an Old Friend

-
Calibrate Milliamp Instruments Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA; Read 0.00 to 52.00 mA,
-99.99 to 99.99 V Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters
-
Calibrate with Confidence - Accurate
to ±0.025% of Span at 4.000 & 20.000 EZ-CHECK outputs
-
Easy-to Read Backlit Display - Use in
the Plant, Field or Shop Includes Rubber Boot, Attached Test Leads & free NIST Certificate of
Calibration Low profile switches resist accidental damage
-
Simple Battery Changes
Separate compartment for no-tool battery changes with four inexpensive
“AA” batteries
-
Optional Accessories
AC Adaptor 120 V (020-0101); 240 V (020-0100); NiMh Batteries & Charger
120 VAC/12V DC (020-0103) Carrying Case (020-0205); Calibration report with test data
Improvements over 334s from other manufacturers include backlit display,
better long term stability, accuracy, reliability & ruggedness plus improved
battery life. PIECAL 334 is the perfect replacement for your worn out mA calibrators!
.......................................................................................................................................
Keep Power Plant 10-50 mA loops up
with the Model 535

-
Calibrate Milliamp & Voltage
Instruments Source & Read 0.000 to 52.000 mA & -25.00 to 125.00% of 10-50 and
4-20 mA with five digit display Source 0.000 to 20.000 V & Read -99.99 to 99.99 V, Simulate 2-Wire
Transmitters, Power & Read Transmitters Menu selectable 250 Ohm resistor for HART compatibility
-
Stroke 10-50 mA valves and power
transmitters Built-in 45 Volt power supply delivers the power to operate your
I/Ps where other calibrators fail
-
Calibrate with Lab Accuracy -
Accurate to ±(0.025% of Reading + 4 lsd) - within 0.01 mA
-
Includes everything you need
AC Adaptor 120 V (020-0101) or 240 V (020-0100); Carrying Case with
Shoulder Strap (020-0204), Test Leads (020-0207) and Certified Test Data
-
Optional Accessories
NiMh Batteries & Charger 120 VAC/12V DC (020-0103)
.......................................................................................................................................
Milliamp Loop Diagnostic
Calibrators
Locate hidden loop problems with
the PIECAL 334Plus and get tighter calibrations with the Evolutionary PIECAL 434!

-
Calibrate Milliamp Instruments
Source & Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA
with five digit display Read -99.99 to 99.99 V; Simulate 2-Wire Transmitters, Power & Read
Transmitters Menu selectable 250 Ohm resistor for HART compatibility
-
Calibrate with Lab Accuracy -
PIECAL 334Plus accurate to ±(0.05% of Span) - within 0.01 mA
PIECAL 434 accurate to ±(0.01% of Reading + 0.002 mA) PIECAL 434 is more accurate than similar calibrators - within ±0.004
mA at 20 mA output!
-
Locate Loop Current Leakages
- Automatic indication of Loop Current and Leakage Current (US
Patent #7,248,058). Measure ground current leakage from faulty
wiring, flooded conduit and corrosion bridges to help you decide if
there is a
wiring problem (diagrams below).
-
Faster Calibrations - Three
output EZ-CHECK switch. 2 speed EZ-DIAL; Stepping & Ramping
-
Easy-to-Read Backlit Display
- Includes Boot, Leads & free NIST Certificate of Calibration
-
Optional Accessories
- AC
Adaptor 120 V (020-0101); 240 V (020-0100) NiMh Batteries & Charger 120 VAC/12V DC (020-0103); Calibration
report with test data Carrying case (020-0205) is included with PIECAL 434 and optional
with PIECAL 334Plus
.......................................................................................................................................
Calibrate & Troubleshoot
Loop Problems with the Model 532

-
Calibrate Milliamp & Voltage
Instruments Source to 24.000 mA & 24.000 Volts DC; Read 0.000 to 24.000
mA, 0.000 to 24.000 V, 24.01 to 30.00 V Simulate 2-Wire Transmitters, Power & Read 2-Wire Transmitters;
250 Ohm resistor - HART compatibility
-
Calibrate with Confidence
Current: Accurate to ±(0.012% of Reading + 0.002 mA);
Voltage: Accurate to ±(0.012% of Reading + 0.004 V)
-
Troubleshoot Loops & Find
Ground Faults Loop diagnostics take dynamic loop readings under operating
conditions (US Patent #7,248,058). Automatic indication of Loop
Current, DC Voltage, Resistance and Leakage Current. Displays AC
Volts & presence of HART.
-
Locate Loop Current Leakages
- Find ground current leakage - faulty wiring, flooded conduits
& corrosion bridges.
-
Faster Calibrations -
Select 3 outputs with EZ-CHECK switch. 2 speed EZ-DIAL plus
Stepping & Ramping Includes Attached Test Leads, Carrying Case (020-0204) & free
NIST Certificate of Calibration
-
Optional Accessories - AC
Adaptor for 120 VAC (020-0101); AC Adaptor for 240 VAC
(020-0100); Calibration report with test data
Typical
problem found with Loop Diagnostics
If you find a loop where the
transmitter is calibrated correctly but all the readings
elsewhere in the loop have a fixed offset this is due to a Zero
Shift. This zero shift is typically caused by some current in
the loop bypassing the transmitter. This might be caused by
ground faults, moisture or corrosion. Turn on Ground Leak Detection and use the PIECAL 334Plus, 434 or
532 to power up the loop. Any current that isn’t controlled by
the transmitter or other current control element will be
indicated as leakage on the calibrator’s display. .......................................................................................................................................
Thermocouple Calibrators
and Sources
Evolutionary PIECAL 322-1
& 422 Automated T/C Calibrators

-
PIECAL 422 - Source and Read
Fourteen T/C Types plus mV J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) & P (Platinel);
-13.000 to 80.000 mV
-
PIECAL 322-1 - Source and
Read Four T/C Types plus mV J, K, T, & E; -13.000 to 80.000 mV
-
Calibrate with Confidence -
Resolution of 0.1° F & C; Accurate to 0.2°
-
Faster Calibrations -
Instantly select three outputs with EZ-CHECK switch Easily find trip points with two speed EZ-DIAL & Automatic
Stepping.
-
Easily Change T/C Types &
Scale - Double click to select T/C type & °F & C
-
Easy-to-Read Display - Turn
on the backlight to read in dark areas of the plant
-
Use in the Plant, Field or
Shop - Low profile switches resist accidental damage.
Includes Rubber Boot, Carrying case (020-0205), mV Test
Leads & free NIST Certificate of Calibration.
-
Simple “No Tool” Battery
Changes - four inexpensive “AA” batteries
-
Verify Cold Junction
Temperature & Output (422 Only) Secondary display of compensated Millivolt setting and cold
junction temperature
-
Optional Accessories Wire & Mini T/C Plug: J, T, E, K (020-0202); B, R/S, K
(020-0203); NiMh Batteries & Charger 120 VAC/12V DC
(020-0103); Calibration report with test data
.......................................................................................................................................
Thermocouple Source
PIECAL
521B
-
Source Multiple
Thermocouple Types plus mV J, K, T, E, R, S, N, B, G, C, D, L, U and P; -13.000
to 80.000 mV
-
Calibrate with
Confidence Resolution of 0.1° F & C; Accurate to 0.4°; Backlit
display Included with PIECAL 520B & 521B: mV Test Leads & free
NIST Certificate of Calibration.
-
Faster Calibrations
Instantly select three outputs with EZ-CHECK switch Easily find trip points with two speed EZ-DIAL
-
Optional Accessories
for 520B & 521B Rubber Boot (020-0209), Carrying case (020-0205) Wire & Mini T/C Plug - J,T,E,K (020-0202), Types B,R/S,K
(020-0203), NiMh Batteries & Charger 120 VAC/12V DC
(020-0103), Calibration report with test data Individual Wire & Mini T/C Plug - Choose J,K,T,E,R/S,N
or B (020-0210-*)
PIECAL
520B
-
Source Only -
Single Thermocouple Type plus mV Choose from Types J, K, T, E, R, S, N, B, G, C,
D, L, U or P (Optional boot shown)
More than a
Simple Boot
-
Rubber boot
adds more than just protection The PIE Rubber boot makes it easier to hold
in your hand or when wearing gloves and provides
protection against accidental falls or when
banging around in your toolbox. A swing out stand is handy when you are working
on a bench.
-
Boot included
with many models and optional for others Included with PIECAL 820, 334, 334Plus, 434,
422, 322-1, 311 & 211 Optional with PIECAL 510, 511, 520 &521 Get Tilt Stand & Extra Protection with Optional
Boot
Get Tilt Stand &
Extra Protection with Optional Boot
.......................................................................................................................................
RTD
Calibrators and Sources
Evolutionary PIECAL 211 & 311 Automated RTD
Calibrators
-
Calibrate
with Ease - Resolution to 0.1° F & C;
Accurate to 0.2°
-
Source
and Read Multiple RTD Curves plus Ohms
Platinum 100 W: a=1.3850, 1.3902,
1.3926; Platinum 1000 W: a=1.3850, 1.3750 Copper 10 & 50 W; Nickel 110 & 120 W; 0.00
to 4001.0 W (PIECAL 211 limited to 2001.0 W) Custom ranges available - consult factory
-
Automatically Detect 2, 3 & 4 Wire
Connections Troubleshoot sensor connections & find
broken wires with patented technology
-
Guaranteed Compatible with all
Instrumentation Works with Rosemount & Honeywell Smart
Transmitters, PLCs, DCSs, Multi-Channel
Recorders and other pulsed excitation
devices
-
Faster
Calibrations - Instantly select three
outputs with EZ-CHECK switch Easily find trip points with two speed EZ-DIAL
knob & Automatic Stepping
-
Easily
Change RTD Types & Scale - Double click
to select RTD Type & °F & °C
-
Verify
RTD Temperature & Output (311 Only) -
Secondary display of Ohms
-
Easy-to-Read Display
- Turn on the
backlight to read in dark areas of the plant
-
Simple
“No Tool” Battery Changes - four
inexpensive “AA” batteries
-
Use in
the Plant, Field or Shop - Includes
Rubber Boot, RTD Wire Kit (020-0208),
Carrying Case (020-0205) & free NIST
Certificate of Calibration. Optional: NiMh
Batteries & Charger 120 VAC/12V DC
(020-0103); Calibration report with test
data
.......................................................................................................................................
RTD
Simulator
PIECAL
511B
-
Simulate Multiple RTD Curves plus Ohms
Pt 100 W:
a=1.385,1.3902,1.3926,1.3916; 1000 W:
a=1.385, 1.375 Copper 10 & 50 W; Nickel 110 & 120 W;
0.000 to 400.000 Ohms
-
Calibrate with Confidence
Resolution of 0.1° F & C; Accurate
to 0.3°; Backlit display Included with PIECAL 510B & 511B: RTD
Wire Kit (020-0208) & free NIST
Certificate of Calibration. Optional Accessories: Rubber Boot
(020-0209); Carrying case (020-0205);
NiMh Batteries & Charger 120 VAC/12V DC
(020-0103); Calibration report with test
data
-
Faster Calibrations
Instantly select three outputs with
EZ-CHECK switch Easily find trip points with two speed
EZ-DIAL knob

PIECAL
510B
-
Simulate Only - Single RTD
Curves plus Ohms Choose any single type from those
listed under PIECAL 511B (Optional boot shown)
More than a Simple Boot

-
Rubber boot adds more than just
protection The PIE Rubber boot makes it
easier to hold in your hand or when
wearing gloves and provides
protection against accidental falls
or when banging around in your
toolbox. A swing out stand is handy when you
are working on a bench.
-
Boot
included with many models and
optional for others Included with PIECAL 820, 334,
334Plus, 434, 422, 322-1, 311 & 211 Optional with PIECAL 510, 511, 520
&521 Get Tilt Stand & Extra Protection
with Optional Boot
.......................................................................................................................................
Dual
Thermocouple and RTD Calibrator
High Resolution & Accuracy 525
Thermocouple & RTD Calibrator
-
Calibrate with Precision - High
resolution to 0.1° and 0.01° F & °C;
Accurat e
to 0.2°
-
Source and Read Multiple
Thermocouple Types plus mV J, K, T, E, R, S, N and B;
-13.000 to 80.000 mV
-
Source and Read Multiple RTD Curves
plus Ohms Platinum 100W: a=1.3850, 1.3902,
1.3926; Copper 10 & 50W; Nickel 110
& 120W; 0.000 to 400.000 Ohms
-
Automatically Detect 2, 3 & 4 Wire
Connections Troubleshoot sensor connections
& find broken wires with patented
technology
-
Guaranteed Compatible with all
Instrumentation Works with Rosemount & Honeywell
Smart Transmitters, PLCs, DCSs,
Multi-Channel Recorders and other
pulsed excitation devices
-
Faster Calibrations - Instantly
select 3 outputs with EZ-CHECK
switch; 2 speed EZ-DIAL; Auto Stepping. Includes Carrying Case
(020-0205); RTD Wire Kit (020-0206)
& free NIST Certificate of
Calibration
-
Optional Accessories - Wire &
Mini T/C Plug: J, T, E, K
(020-0202); B, R/S, K (020-0203);
Calibration report with test data
.......................................................................................................................................
Frequency Calibrator
-
Calibrate Flow Meters and
Frequency Instruments
Generate Sine Waves, Zero
based & Zero crossing Square
Waves; Adjust amplitude from 100
mV to 12V p-to-p
-
Read with Built-in Frequency
counter - Measures waveforms
from 0.1V-120V peak-to-peak
-
Calibrate with confidence
- Accurate to ±0.005% of Range
-
Compatible with Process
Signal Ranges 0.001 kHz to 20.000 kHz; 0.1
Hz to 2000.0 Hz; 0.01 Hz to
200.00 Hz 0.1 CPM (Counts-per-minute) to
2000.0 CPM; 1 CPH
(Counts-per-hour) to 20000 CPH
-
Calibrate Totalizers
-
Totalize Inputs/Outputs from 1
to 99999 counts in 0.1 to 100.0
minutes
-
Includes: Attached Leads,
Carrying Case & free NIST
Certificate of Calibration
-
Optional Accessories - AC
Adaptor for 120 VAC (020-0101);
AC Adaptor for 240 VAC
(020-0100); Calibration report
with test data
.......................................................................................................................................
|
|
 |
 |
|